75mm Water Seal Gully with Horizontal Outlet for Tiled or Stone Floors

TSG1T6SS 150mm Square Polished Stainless Steel
TSG1T6SS 150mm Square Polished Stainless Steel
TSG1T6SS
TSG1-T150SS 150mm Square Polished Stainless Steel without securing screws
TSG1-T150SS
TSG1T6WH 150mm Square White ABS
TSG1T6WH
TSG1-R125SS 125mm Circular Polished Stainless Steel
TSG1-R125SS
75mm Water Seal Trapped Gully, Tile/Grating with removable Grid, 2" Horizontal Outlet and 2" x 1½" Socket Reducer
  • Available with Polished Stainless Steel or White ABS tile or Circular Polished Stainless Steel grating.
  • 75mm Water Seal
  • 2" BS EN 1329-1:2020 Solvent Weld Horizontal Outlet
  • Supplied with 2" x 1½" socket reducer
  • Tiled or stone floor gully suitable for concrete and suspended timber floors
  • Manufactured in ABS to the highest quality
  • Overall height 130mm
  • Flow rates of 48 litres per minute exceed the minimum requirement of BS EN 1253-1:2015 and are variable dependent on the cover plate used
  • Ideal for showers in domestic wet rooms, disabled and student accommodation, bathroom pods, retirement and care homes, hotels, hospitals and sport and leisure
Tile
Product Code
150mm Square Polished Stainless Steel
TSG1T6SS
150mm Square Polished Stainless Steel without securing screws
TSG1-T150SS
150mm Square White ABS
TSG1T6WH
125mm Circular Polished Stainless Steel
TSG1-R125SS

Assembly & Features

Features - Tiled Flooring Prods

Installation Guidelines

Installation - Tiled Flooring

Tiled Floors

  • The minimum dimension between the gully flange and top surface of the gully tile or grating - which needs to be flush with the flooring - is 13mm. This size cannot be reduced but if required, the gully tile or grating can be raised. To do this, remove the centre from the dust cap/extension ring and solvent weld the extension ring to the upstand of the clamp ring. If additional height is necessary, an appropriate length of 110mm pipe can be solvent welded between the extension ring and the underside of the gully tile or grating.
  • Ensure the gully body is fully supported. Do not rely solely on the gully flange for support.
  • A good quality waterproofing membrane should be employed to prevent water penetration to the floor structure. Ensure that the underside of the membrane is sealed to the gully flange and secured by the clamp ring to the gully body.
  • The clamp ring has weep holes to allow any moisture to discharge into the gully.

Download our latest Wet Room Brochure

Wet Room Brochure

Contact Us

McAlpine plumbing products are designed and manufactured to be installed by qualified plumbing professionals. On this basis we cannot accept installation queries from the general public. Please contact your local McAlpine stockist or a qualified plumbing professional. For all other enquiries please fill out the form below.